POWER VENTER SYSTEM
Model: PVO-300, PVO-600
Included is one ETL and cETL listed Power Venter to be used primarily with a
single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO
may be used to common vent multiple appliances with the addition of a Control
Kit. Please consult Field Control’s Technical Support for other options.
TYPICAL VENTING SYSTEM COMPONENTS
One PVO Series Power Venter with pre-wired controls; adjustable post
purge relay timer, adjustable draft proving switch, direct access terminal
blocks, and piping tee for multiple appliance systems.
• Side Wall Vent Hood (Not included) • Spill Switches (Not included)
• CK-Series Control Kit for multiple appliance venting (Not Included)
CONTENTS PAGE
Unit Specifications 2
System Operation 2
Power Venter Sizing 3
Installation Safety Instructions 4
Installation of Power Venter 5
General Wiring Instructions 5-6
Airflow Adjustments 7
Pressure Switch Adjustments 7
Post Purge Timer Adjustments 7
Multiple Appliance Systems 7
General Installation Inspection 8
Maintenance 8
Replacement Parts List 9
Venting System Operational Information 10
Installation Information 10
This device MUST be installed by a qualified agency in accordance with the manufacturers installation
instructions.
The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is
engaged in, and is responsible for, the installation and operation of gas appliances, who is experienced in such work, familiar with all
the precautions required, and has complied with the requirements of the authority having jurisdiction.
DO NOT DESTROY
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - POWER VENTER SYSTEM

2630 Airport Road · Kinston, NC 28504 Phone: 252-522-3031· Fax: 252-522-0214 www.fieldcontrols.com POWER VENTER SYSTEM Model: PVO-300, PVO-600 Include

Page 2 - (Model SWH-1)

Page 10REPLACEMENT PARTS LIST The following items are available for replacement, if necessary. REPLACEMENT PARTS LIST DESCRIPTION PVO-300 PVO-600 M

Page 3

Page 11NOTES

Page 4

Page 12 P/N 46311800 Rev E 11/07

Page 5 - ENERAL WIRING INSTRUCTIONS

Page 2 UNIT SPECIFICATIONS (See Table 1 and Figure 1) Table 1 UNIT DIMENSIONS (INCHES) MODEL “H” “W” “D” I/O* PVO-300 7.50 9.25 7.00 4/4 PVO-60

Page 6 - Diagram C

Page 3POWER VENTER SIZING In order to choose the correct size power venter for a particular installation, the total input firing rate and total equiv

Page 7

Page 4INSTALLATION SAFETY INSTRUCTIONS CAUTION: This device must be installed by a qualified installer in accordance with the manufacturer's in

Page 8

Page 5INSTALLATION OF POWER VENTER CAUTION: Failure to install, maintain and/or operate the power venting system in accordance with manufacturer&apo

Page 9

Page 6Diagram BDiagram C

Page 10

Page 7MULTIPLE APPLIANCE SYSTEMS When using one PVO power venter to common vent more than one appliance, a Control Kit is required for each additiona

Page 11

Page 8GENERAL INSTALLATION INSPECTION Follow recommended procedures for safety inspection of a heating appliance in accordance with the National Fuel

Page 12 - P/N 46311800 Rev E 11/07

Page 9PV SERIES POWER VENTER: VERTICAL VENTING OPTION Diagram D illustrates correct and incorrect installation of PV series venter in vertical vent c

Related models: PVO-300

Comments to this Manuals

No comments